Eaton 93PM | Eaton 93PM UPS 30-500 kVA
- Model: Eaton 93PM UPS
- Capacity: 30–500 kVA 27–450 kW
- Input: 208/220/380/400/415/480 V 3-phase
- Outputs: Hardwired (configurable to IEC/NEMA)
- Battery: VRLA or lithium-ion 9 Ah hot-swappable
- Connectivity: USB serial optional Gigabit Network Card-MS
- Dimensions: 560–1880 x 1010 x 1876 mm
- Weight: 280–900 kg
Eaton 93PM UPS 30-500 kVA
Power and Performance
The Eaton 93PM UPS offers 30–500 kVA (27–450 kW, 0.9 power factor, 1.0 for select models), ideal for data centers and critical infrastructure. Its double-conversion topology ensures zero transfer time and clean power. Runtime is up to 15–30 min with integrated batteries, extendable via EBCs. Efficiency reaches 97% in double-conversion mode and 99% in Energy Saver System (ESS) mode, reducing costs. HotSync parallels up to 8 units for scalability. Users praise uptime but note high initial costs. Perfect for mission-critical applications.
Connectivity and Protection
It features hardwired outputs (configurable to IEC/NEMA) with surge protection (IEC 61643-11). Connectivity includes USB, serial, and optional Gigabit Network Card-MS for remote monitoring via Brightlayer Data Centers suite. Input power factor of 0.99 and 5% ITHD ensure generator compatibility. Integrated maintenance bypass and distribution cabinets simplify installation. Users value cybersecurity compliance but note optional cards add cost. Ideal for large data centers and medical facilities.
Design and Features
Weighing 280–900 kg, the modular design (600 x 1010 x 1876 mm for 50–150 kW) occupies up to 30% less floor space. Features include hot-swappable VRLA or lithium-ion batteries, ABM technology (extends battery life ~50%), and a graphical LCD. Front-access maintenance reduces MTTR to ~30 min. Thermal management options (top/bottom air exhaust) lower cooling costs. Users like the compact footprint but note weight challenges. UL 924 compliant for emergency lighting (select SKUs).
Eaton 93PM UPS: All Features
| Capacity | 30–500 kVA 27–450 kW |
|---|---|
| Topology | Double-conversion online |
| Outputs | Hardwired (configurable to IEC/NEMA) |
| Battery | VRLA or lithium-ion 9 Ah hot-swappable |
| Connectivity | USB serial optional Gigabit Network Card-MS |
| Features | LCD display HotSync ABM maintenance bypass surge protection (IEC 61643-11) ESS mode UL 924 (select SKUs) |
| Warranty | 1 year (extendable with service plans) |
Eaton 93PM UPS: All Specifications
| Model | Eaton 93PM UPS (30 40 50 60 100 120 150 160 200 400 500 kVA) |
|---|---|
| Catalog Numbers | 93PM-30 93PM-40 93PM-50 93PM-60 93PM-100 93PM-120 93PM-150 93PM-160 93PM-200 93PM-400 93PM-500 |
| Capacity | 30–500 kVA 27–450 kW |
| Power Factor | 0.9 (1.0 for select models) |
| Topology | Double-conversion online |
| Input Power Factor | 0.99 <5% ITHD |
| Battery | VRLA or lithium-ion 9 Ah hot-swappable |
| Battery Management | ABM with 3-stage charging automatic battery test |
| Runtime | Up to 15–30 min at full load (extendable with EBCs) |
| Extended Battery Capability | External Battery Cabinets (EBCs up to 8 small/large welded IBC-SW/IBC-LW) |
| Connectivity | USB serial relay optional Gigabit Network Card-MS |
| Surge Protection | IEC 61643-11 compliant |
| Display | Graphical LCD for status and energy metering |
| Efficiency | Up to 97% double-conversion 99% ESS mode |
| Audible Noise | <65 dB at 1 m |
| Dimensions | 50–150 kW: 560–600 x 1010 x 1876 mm; 160–500 kW: 760–1880 x 1010 x 1876 mm |
| Weight | 280–900 kg (model-dependent) |
| Protection Class | IP20 |
| Certifications | IEC EN 62040-1 IEC EN 62040-2 CE UL Energy Star UL 924 (select SKUs) |
| Warranty | 1 year (extendable with service plans) |
| Software | Brightlayer Data Centers suite Intelligent Power Manager |
| Accessories | EBCs (IBC-SW IBC-LW) maintenance bypass (IAC-B IAC-BD) distribution cabinet (IAC-PD) rail kits |
| Package Contents | UPS USB serial cables user manual software CD |





-170x170.png)